Synopsis
HVAC School is the ever growing online source for real training topics for technicians in the Air-conditioning, Heating and Ventilation Fields. In the podcast, we will share recorded training, tech ride alongs, share challenging diagnostic scenarios. All to help make the industry, your company, and your truck a better place to be.
Episodes
-
A FASCINATING New Power Generation / Water Heating Solution w/ Enginuity
02/03/2022 Duration: 33minJacques Beaudry-Losique, the CEO of Enginuity Power Systems, joins Nathan Orr live at AHR 2022. Enginuity manufactures energy-efficient engines that produce more power than traditional engines and recover waste heat to act as water heaters. Enginuity engines can run on propane and natural gas to help you run almost entirely off the grid and participate in electricity buyback programs. These units operate independently of the electrical grid and can act as generators during power outages and have a small footprint. However, a backup battery system is recommended for these units to maximize efficiency. Enginuity has a residential and commercial line. The E | ONE is best suited for residential applications, and the E | TWO is better for heavier commercial applications. The U.S. Army has been one of the most prominent supporters of Enginuity, which also manufactures its units exclusively in America. Distribution is done through a third party, including business owners and technicians; Enginuity doesn’t deal direc
-
Samsung Ductless LIVE From AHR - Short #139
01/03/2022 Duration: 20minRick Nadeau, Director of Training and Technical Services at Samsung, talks with Kaleb Saleeby live from AHR. He explains some of the exciting ductless solutions that Samsung has to offer. Samsung’s WindFree mini-split systems work with VRF systems or as normal ductless units. The WindFree product line is best known for preventing drafts due to microholes. These systems come in one-way and four-way cassettes and work very well for sensitive environments like nursing homes and bedrooms. These units also have humidity sensors that let the units know when it would and wouldn’t be acceptable to go into WindFree mode. Samsung’s systems may also have occupancy sensors, which determine when they can turn on to provide comfort and flexibility. The systems also have the capability to determine when the system is losing refrigerant to prevent major environmental and performance issues. Samsung has MaxHeat technology, which allows a system to have 100% heating capacity in low-ambient temperatures as low as -30 degrees F
-
How to ACTUALLY Measure Airflow w/ Steve Rogers and Eric Kaiser
27/02/2022 Duration: 29minSteve Rogers from The Energy Conservatory (TEC) joins Eric Kaiser to talk about airflow measurement at AHR 2022. Steve is an expert in fluid dynamics and flow measurement, and he is a trainer in addition to being the president and CEO of TEC. Airflow is one of the most critical elements of an HVAC system; it allows us to move the correct amount of BTUs to condition the air properly. We have various ways of measuring system airflow and airflow to a space. We can use the TrueFlow grid for the former and flow hoods for the latter. When it comes to measuring airflow, calibrating the instrumentation is crucial. TEC uses a laboratory-grade orifice plate to calibrate the tools. So, the calibration process manages to yield high accuracy while using a low-maintenance device. To begin measuring airflow properly, start taking the total external static pressure (TESP) and looking at fan charts. TESP doesn’t actually measure airflow, but it provides an idea of what the airflow might be like, and it’s a practical, useful m
-
Commercial Rack Refrigeration Component Identification
24/02/2022 Duration: 52minBrett Wetzel and Kevin Compass from the Advanced Refrigeration Podcast join us to discuss commercial rack refrigeration and identify components. In supermarket racks, we typically have anywhere from 2-5 compressors on a single rack (with multiple evaporators, metering devices, and sometimes even condensers). These compressors may come in several varieties (including screw and scroll) and be digital or have VFDs. They also have common suction and discharge headers. The compressors all share oil from a single system. Oil separators can come in three varieties: centrifugal, impingement, and coalescing (most efficient). The separator would feed into the reservoir, which stores oil. Many rack systems use several different valves. Check valves to direct the refrigerant flow, especially on heat reclaim systems and split condensers. In some cases, there is a three-way valve or a solenoid valve that controls or stops the refrigerant flow. LDR (liquid differential regulating) valves maintain the required differential
-
Universal Boards and Controls w/ Eric K. and Jim F. LIVE from AHR
23/02/2022 Duration: 29minJim Fultz from Emerson joins Eric Kaiser at AHR to share his knowledge of universal boards and controls. Jim’s work focuses on electronic controls within the White-Rodgers brand. Common White-Rodgers universal controls include the SureSwitch and universal defrost controls. The SureSwitch also has sealed contacts, which prevents insects and debris from shorting out the contacts. This past year, White-Rodgers debuted the All-Spark, which doesn’t need electricity to be powered up and can be programmed right out of the box. The All-Spark works on all sorts of appliances, not just boilers and furnaces. Universal controls are generally safe to put in combustion units, even gas furnaces. New controls go through rigorous testing before they hit the market. The controls MUST stay within the OEM’s guidelines; otherwise, they won’t make it to the market. Sometimes, when boards need to be replaced, we also need to upgrade the igniter to match the voltage of the new board. The goal of universal controls is to save time a
-
Malco - New Tools and Education Focus with Rich Benninghoff - Short #138
22/02/2022 Duration: 15minIn this short podcast from AHR 2022, Leilani Orr and Eric Kaiser talk with the president and CEO of Malco Tools, Rich Benninghoff. Rich discusses some of the exciting new tools that Malco is bringing to the market and some plans for the future, especially when it comes to education. Malco has developed the Eagle-Grip, which is a set of locking-handle pliers made in the USA with American steel. The tool is currently in a soft launch; it is currently receiving a lot of interest, so Malco has been building up inventory, forming partnerships across industries, and collecting market feedback. One of Malco’s most exciting products is the C-RHEX line of cleanable, reversible magnetic hex drivers. These hex drivers come in many sizes and are easy to clean; the cleanable and magnetic features are especially important, as the buildup of metal resin and clippings can decrease tool longevity and effectiveness without proper cleaning. Malco has also been focusing on trade schools and education through “Look Good, Feel Goo
-
HFC Phasedown W/ Jason O and Nathan O LIVE from AHR
20/02/2022 Duration: 28minJason Obrzut joins Nathan Orr with the HVAC School podcast live from AHR. In this episode, they discuss A2L refrigerants and upcoming regulations. They explain what a “flammable” refrigerant really is and why the industry may be making a bigger deal of the new regulations than is really necessary. Whenever regulations are passed, we need to understand that there is a notable transition period. This period will mostly be about training, and the only people who should be working on the new equipment should be the most experienced technicians. A2L refrigerants are mildly flammable, non-toxic refrigerants, including R-32. Flame propagation is possible but quite rare for A2L refrigerants under normal operating conditions. However, even A1 refrigerants can propagate flame under the right conditions (just not ones we’d normally see). Many countries all over the world have been using A2L refrigerants for much longer than we have, so we can make those refrigerants work safely. All trades will evolve, and we need to be
-
HVAC Training Past, Present & Future w/ David Holt
17/02/2022 Duration: 50minDavid Holt with NCI returns to the podcast to discuss the evolution of HVAC training; we cover the past, present, and the possible future of training in the industry. In the past, we had a lot of hands-on training, whether it was one-on-one or in a traditional classroom setting. These learning practices remain beneficial today, especially since many uninformed practices are still prevalent in the industry today (charging to beer-can cold, condemning TXVs without a second thought, etc.). However, the pandemic has forced us to consider online and remote training in the present. The content has also changed from the past; we are a lot more aware of combustion and airflow nowadays, which are very important topics for safety and efficiency. Those training topics allow us to understand what we’re doing when we take the “vital signs” of the equipment. Being better versed in basic and advanced diagnostics will also give us a more holistic understanding of the HVAC equipment as a system, which can help us truly optim
-
Proper System Commissioning w/ Jim Bergmann from AHR Live
16/02/2022 Duration: 27minJim Bergmann returns to the HVAC School podcast live from AHR 2022 to discuss a bit about proper system commissioning. He explains the commissioning mindset and some helpful procedures. Successful system commissioning starts with the mindset. A good commissioning organization broadens its vision; instead of focusing on the appliance, techs and installers focus on the system. Commissioning early on saves time later; you can focus on installs and maintenance instead of callbacks, and your organization can make more money as a result. When installing and testing new piping, make sure you insulate the tubing properly and keep the lines CLOSED OFF to the atmosphere. Measuring the line set is also critical for weighing the charge properly, as long lines have special considerations. When doing the decay test, use a quality vacuum rig and try to keep the micron gauge as far away from the pump as possible. Cleaning line sets also helps your vacuum results by getting rid of oil and moisture within the lines. Flowing ni
-
3D Load & Energy Calcs w/ Duct Design
15/02/2022 Duration: 26minRuss King joins us for a short podcast episode about using 3D load and energy calculations with duct design. Russ has developed the Kwik Model 3D software program with the help of his son, Connor. Kwik Model 3D uses a video game platform to build a house out of boxes instead of a sketch. The software has evolved and been integrated into EnergyGauge to do load and energy calculations based on a house’s geometry. Kwik Model makes it easy and fun to create that geometry profile for a home, which makes building design and load calculation attractive to technicians. Software like Kwik Model may especially become popular as Generation Z steps into the workforce; we can expect the learning curve to be quite shallow for the digital generation. The Manual J calculation uses the home’s characteristics in Kwik Model and does all of the mathematical calculations in EnergyGauge for an advanced load calculation. KwikModel then receives those calculations for each room. Then, you can draw the ductwork and use an auto-size f
-
A History in HVAC Chemical Chemistry w/ John & Mike Pastorello
13/02/2022 Duration: 39minIn this live podcast from AHR Expo 2022, John and Mike Pastorello of Refrigeration Technologies give us a history lesson in HVAC chemical chemistry. They also explain what it takes to make a truly beneficial product for the industry. From the beginning, Refrigeration Technologies has focused on solving problems instead of jumping on product trends. Before Big Blu was introduced, technicians had to rely on less-than-reliable electronic leak detectors and poor-quality soap bubbles. So, John Pastorello learned about the fundamentals of foaming and bubbles to create a leak reactant that works, even creating microbubbles for tiny leaks. Nylog has a similar origin story, and it has evolved to work for both mineral oil (red) and POE (blue) systems. As with Big Blu, John ran several tests to make sure the Nylog was compatible with HVAC equipment and did not cause contamination. The Viper Pan & Drain Treatment was developed to replace pan tabs, which failed to remove the dead biological material in drains. The spr
-
Upgrades and Proposals That Lead to Clarity & Profit w/ Michael Housh
10/02/2022 Duration: 01h05minMichael Housh returns to the podcast to discuss upgrades and proposals that are worth considering. These upgrades and proposals can actually benefit the customer AND lead to clarity and profit without turning you into a white-shirt tech. When assessing a system for replacement, it’s a good idea to look at the airflow side by measuring static pressure AND using a flow grid; these practices set you apart from others and supply you with good data about system sizing. Filtration is another area where you can consider upgrades and proposals; customers generally want to keep their air clean and may be happy to pay for better filtration, fresh air, and de/humidification. Surge protection is a high-value upgrade that many customers may benefit from, especially if the electrical company allows overvoltage or the customer has a voltage-sensitive ECM or inverter system. Some upgrades are useful and can be offered automatically (the customer can decline it); depending on the climate, a humidifier or dehumidifier may fit
-
Free Tech Support w/ Clifton Beck
08/02/2022 Duration: 24minIn this short podcast episode, Clifton Beck joins us to talk about Bluon’s free tech support and resources available to technicians and installers. Clifton has been very in touch with the HVAC technician community since he got his start in the trades, and he has taken that into tech support. He has noticed that the inefficiency in our industry tends to come from poorly learned practices, and working in tech support is a way for him to do his part to spread better practices while helping others. Lately, Bluon has become more of a tech support business. The new shift to focus on innovation has prompted Bluon to shift from making equipment more efficient to making technicians more efficient. The whole HVAC industry relies on that progression from developing on equipment to people. Tech support consists of answering calls but also creating training videos and creating layers of technician education and development. Manuals are just part of the picture; tech support helps with part identification AND the sequence
-
Blower Doors Don't Need to Be So Confusing w/ Genry Garcia
03/02/2022 Duration: 44minGenry Garcia returns to the podcast to talk about blower doors and why ACH50 may needlessly complicate efforts to tighten a building envelope. A large element of indoor comfort comes down to controlling the load, especially the latent load. Even though we can control indoor humidity sources, we may also deal with infiltration, which contributes to a high latent load and decreases comfort. The blower door test comes in when we can no longer control the load and need to determine how much infiltration is happening. When using blower doors, we would typically use an ACH50 test, which takes the CFM50 (cubic feet per minute that the blower door moves to get the house up or down to 50 Pascals) and translates it to air changes per hour at 50 Pa. To do that, you would need to find the volume of the space, which adds hurdles that the HVAC technician needs to deal with. However, Genry prefers using the CFM50 and factoring in the square footage and LAIR (leakage area infiltration ratio) to determine how tight a house is
-
Introduction to Psychrometrics w/ Eugene Silberstein
01/02/2022 Duration: 46minEugene Silberstein, a co-author of Refrigeration and Air Conditioning Technology (RACT manual), joins the podcast to give us an introduction to psychrometrics. Psychrometrics focuses on the properties of air and its contents, especially as they relate to human comfort. To understand psychrometrics, we need to be able to quantify air: its weight, humidity, pressure, etc. We can do a better job as technicians if we figure out the air’s content and see how it relates to the CFM and overall unit performance. That way, we can have a more holistic view of HVAC performance instead of just focusing on adding or recovering refrigerant to improve performance. The psychrometrics chart helps us understand the conditions of the air based on quantities like water vapor, dew point, and more. The chart may intimidate techs, but it contains a wealth of information that can help technicians understand the air and the customer’s comfort better. Basic psychrometrics can also help us grasp why furnaces don’t actually dry out air;
-
Prepare For Refrigerant Changes w/ Brandon Marshall
27/01/2022 Duration: 24minBrandon Marshall, Chemours’s North American marketing manager for thermal and specialized solutions, joins the podcast to discuss refrigerant changes that are coming and how we can prepare for those. Brandon started in the industry by going to a technical school when he was 14 and has been hard at work ever since, studying light commercial design and going to college in between. Local and global regulations have changed a lot over the years and continue to change as we continue maximizing our equipment’s efficiency. California will soon start switching to low-GWP refrigerant on new equipment in 2025; even R-410A can’t be used in new equipment. We will begin seeing the rise of A2L refrigerants and moving away from the A1 refrigerants that are more detrimental to the environment; we’ll have to focus on safety as we begin working with more flammable refrigerants. As new refrigerants get off the ground, we can expect increased communication between manufacturers and dealers to prepare for the sale of equipment bu
-
The History and Future of Refrigerants w/ Chuck Allgood
25/01/2022 Duration: 44minChuck Allgood with Chemours joins the podcast to cover the history of refrigerants and discuss what the future might hold. In the late 1800s, before Freon, the only refrigerants that were used were industrial chemicals like ammonia, CO2, and sulfur dioxide. DuPont stepped in to provide a better refrigerant for industrial refrigeration (which then spurred the rise of domestic refrigeration), so they created a non-toxic, non-flammable chemical called Freon-12 (CFC R-12) in 1928. However, in the 1970s-1980s, it was discovered that R-12 and other CFCs depleted the ozone layer due to the chlorine content. R-12 production was banned in the 1990s per the Montreal Protocol. HCFCs like R-22 also have chlorine but in smaller concentrations; those phaseouts have been much more recent. Following news of the HCFC phaseout, HFCs and refrigerant blends became more popular because their ozone depletion potentials were 0. Although HFCs don’t deplete the ozone layer, some of them have high global warming potential (GWP). Regul
-
Overcoming Conflict at Work w/ Andy Holt
20/01/2022 Duration: 38minAndy Holt joins the podcast to discuss the ever-relevant topic of overcoming conflict at work. Some people end up in conflicts often, so Andy recommends paying attention to how others react to the conflict you have perceived; if you are much more stressed than everyone else, then you need to look internally, not externally. The first step to overcoming conflict is to slow down and think about your reactions to perceived conflicts. Partaking in bickering and gossip with coworkers creates a negative environment for the entire team; the best way to avoid or resolve conflicts is to handle them directly and sincerely ask the other party to start over. Overall, it’s best to take the high road and take initiative to make things right. When dealing with conflict with bosses, it’s best to separate emotion from the facts and keep discussions simply factual. It’s good to be open, honest, and understand that you can’t control your boss’s response. As a boss dealing with employee conflict, it’s a good idea to avoid firing
-
Commercial HVAC Estimating
30/12/2021 Duration: 27minMatthew and Nick Wavra join the podcast to discuss everything that goes into job estimation in commercial HVAC. Nick has a lot of fieldwork and project management experience, and Matthew has marketing, software, and sales experience, which helps bring in and retain clients. Commercial estimation begins when a mechanical contractor asks for a bid on a job. The estimators go through the spec books, bidding documents, and any addendums to come up with takeoffs and a price. The estimator seeks approval from manufacturers to build the materials, and they use software to come up with an estimate. The pricing updates weekly to stay current and accurate in an economy that’s currently facing inflation. Estimators develop takeoffs for materials and labor; each material has some sort of labor attached to it, though the labor estimates may need to be adjusted as conditions change. Commercial contractors may make mistakes when they miss equipment or elevation considerations (when estimating labor). On-screen takeoff opti
-
Furnace Sequence of Operation - Short 137
28/12/2021 Duration: 07minIn this short podcast episode, Bryan goes over the basic gas furnace sequence of operations. There are a few variations, but the sequence of operations tends to stay consistent across most furnace types. First, a W call from the thermostat calls for heat. The circuit board will then assess the safeties to see if it can bring on the heat without causing flame rollout or other dangerous conditions. If the safety switches are all closed, then the furnace can bring on the heat. However, in some cases, the induced draft motor may come on first in some 80% furnaces. There needs to be a small negative pressure in the induced draft motor housing. To confirm that we have that pressure, a pressure switch will close under the right conditions. Then, ignition begins. In most cases, we use intermittent-spark ignition (ISI) or hot-surface ignition (HSI). It takes some time for these methods to light the pilot, which then lights the main burner. After that, the gas valve opens to fuel the burner. On an ISI system, that’s ab