In today’s short podcast, Bryan discusses the key factors for system performance WITHOUT doing a deep dive into system commissioning. “Performance” refers to system efficiency, capacity, air filtration/cleanliness, longevity, and the ability to match the latent and sensible loads of a space.   System airflow is the main performance factor to consider. To determine proper airflow (CFM), consult Manuals S, J, and D to perform calculations. In general, the absolute lowest limit is around 275 CFM (in extreme dehumidification mode), and the highest limit should be around 525 CFM (in arid climates or at altitude).    You can determine your CFM target after you set up your ECM motor in the design. Then, you can also check airflow indicators: total external static pressure and pressure drop across the filter. The best way to improve airflow is to reduce pressure drop across the filter and build a better return plenum. For improving overall system performance, make sure the ducts are appropriately sized.    System cha