Hvac School - For Techs, By Techs

How to Predict Air Flow Issues in the Sales Process

Informações:

Synopsis

Chris Hughes and Steve Rogers from The Energy Conservatory discuss TEC's TrueFlow technology and its crucial role in predicting airflow issues in the sales process, particularly for heat pump retrofits. They explain how the TrueFlow app helps contractors accurately measure both static pressure and airflow in existing systems, enabling them to predict whether proposed equipment changes will work effectively. This is especially vital when considering the growing trend of replacing gas furnaces with heat pumps, as the airflow requirements can differ significantly. The conversation delves into a detailed example of replacing an 80% efficient 48,000 BTU furnace with a heat pump. They demonstrate how the airflow requirement would nearly double from 652 CFM to 1,200 CFM, potentially causing the static pressure to quadruple due to Fan Law 2 principles. This dramatic increase could lead to significant performance issues if not properly addressed during the system design phase. The experts emphasize that using TrueFlow